- OCPP
- test cases
- tc b 01 cs
TC_B_01_CS — Cold Boot Charging Station - Accepted
Cold Boot Charging Station - Accepted (TC_B_01_CS) — OCPP 2.0.1 OCTT compliance test. The booting mechanism allows a Charging Station to provide some general information about the Charging Station…
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block B. Provisioning, page 27.
Identification
| Field | Value |
|---|---|
| Test case name | Cold Boot Charging Station - Accepted |
| Test case Id | TC_B_01_CS |
| Use case Id(s) | B01 |
| Requirement(s) | B01.FR.01, B01.FR.05, B01.FR.09 |
| System under test | Charging Station |
| Functional block | B. Provisioning |
Description
The booting mechanism allows a Charging Station to provide some general information about the Charging Station to the CSMS on startup AND it allows the Charging Station to request whether it is allowed to start sending other OCPP messages.
Purpose
To verify whether the Charging Station is able to perform the booting mechanism as described at the OCPP specification.
Prerequisite(s)
N/a
Before (preparations)
Configuration State:
- N/a
Memory State:
- N/a
Reusable State(s):
- N/a
Main (test scenario)
| Charging Station | CSMS |
|---|---|
| 1. Execute Reusable State Booted |
Tool validations
N/a
Post scenario validations
- A message to report the state of a connector has been received for all connectors.