TC_E_08_CS — Stop transaction options - EnergyTransfer stopped - StopAuthorized
Stop transaction options - EnergyTransfer stopped - StopAuthorized (TC_E_08_CS) — OCPP 2.0.1 OCTT compliance test. OCPP 2.x.x has a flexible transaction mechanism that allows the transaction start…
Source: OCPP 2.0.1 Part 6 — Test Cases (Core & Advanced Security, FINAL, 2023-06-30) — Functional block E. Transactions, page 143.
Identification
| Field | Value |
|---|---|
| Test case name | Stop transaction options - EnergyTransfer stopped - StopAuthorized |
| Test case Id | TC_E_08_CS |
| Use case Id(s) | E06(S6) |
| Requirement(s) | E06.FR.07, E06.FR.15 |
| System under test | Charging Station |
| Functional block | E. Transactions |
Description
OCPP 2.x.x has a flexible transaction mechanism that allows the transaction start and stop points to be configured differently. This test covers one of the stop options.
Purpose
To verify if the Charging Station stops a transaction when the energy transfer stopped normally and it has been configured to do so.
Prerequisite(s)
- The Charging Station does NOT have the following configuration; The mutability of TxStopPoint is ReadOnly AND (the value EnergyTransfer is NOT set OR (Authorized OR PowerPathClosed) is set).
- If the mutability of TxStopPoint is ReadWrite, then the value EnergyTransfer must be supported.
Before (preparations)
Configuration State:
- TxStopPoint contains EnergyTransfer
Memory State:
- N/a
Reusable State(s):
- State is EnergyTransferStarted
Main (test scenario)
| Charging Station | CSMS |
|---|---|
| 1. State is StopAuthorized |
Tool validations
Step 1:
N/a
Post scenario validations